Inadvertent temporary pacemaker lead placement in aortic sinus


Department of Cardiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India

Correspondence Address:
Nagaraja Moorthy
Department of Cardiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow - 226 014, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1995-705X.126885

Rights and Permissions

Inadvertent placement of pacing leads into abnormal locations is potentially very dangerous. However, in emergency situations and without fluoroscopic guidance, these complications do occur. We report a case of an elderly male who underwent temporary pacemaker lead implantation without fluoroscopic guidance for cardiac arrest, but later the pacemaker lead was found to be in the non-coronary aortic sinus, but still capturing the myocardium. Interestingly, the post-pacing electrocardiography was mimicking atrial pacing.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4280    
    Printed156    
    Emailed0    
    PDF Downloaded100    
    Comments [Add]    
    Cited by others 1    

Recommend this journal