Login | Users Online: 1054  
Home Print this page Email this page Small font sizeDefault font sizeIncrease font size   
Home | About us | Editorial board | Search | Ahead of print | Current Issue | Archives | Submit article | Instructions | Subscribe | Advertise | Contact us
 


 
Table of Contents
CASE REPORT
Year : 2017  |  Volume : 18  |  Issue : 2  |  Page : 47-49  

Pseudo-lesions of a tortuous right coronary artery during percutaneous coronary intervention: Accordion phenomena


Department of Adult Cardiology, Heart Hospital, Hamad Medical Corporation, Doha, Qatar

Date of Web Publication21-Jun-2017

Correspondence Address:
Fahad Alkindi
Department of Adult Cardiology, Heart Hospital, Hamad Medical Corporation, P.O. Box 3050, Doha
Qatar
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/HEARTVIEWS.HEARTVIEWS_44_17

Rights and Permissions
   Abstract 

Guidewire-induced pseudo-lesions are referred to accordion phenomenon and are infrequent occurrences during percutaneous coronary intervention of tortuous coronary arteries. Their occurrence can be a diagnostic challenge to the interventionist and might lead to unnecessary intervention. Ischemia and hemodynamic compromise are possible complications, if not managed promptly. The differential diagnosis includes coronary dissection, thrombus, and spasm. We describe a patient who developed pseudo-lesions of the tortuous right coronary artery in multiple segments during PCI. The pseudo-lesions were refractory to intracoronary nitrogycerin.

Keywords: Accordion phenomena, concertina effect, guidewire-induced coronary spasm


How to cite this article:
Maaly CA, Rafie I, Alkindi F. Pseudo-lesions of a tortuous right coronary artery during percutaneous coronary intervention: Accordion phenomena. Heart Views 2017;18:47-9

How to cite this URL:
Maaly CA, Rafie I, Alkindi F. Pseudo-lesions of a tortuous right coronary artery during percutaneous coronary intervention: Accordion phenomena. Heart Views [serial online] 2017 [cited 2023 Mar 23];18:47-9. Available from: https://www.heartviews.org/text.asp?2017/18/2/47/208669


   Introduction Top


Accordion phenomenon is a transient angiographic pseudo-lesion observed during percutaneous coronary intervention (PCI), usually in tortuous vessel and by stiff guidewire. We present a case of this transient pseudo-lesion in tortuous right coronary artery induced by a soft guidewire.


   Case Presentation Top


A 47-year-old male with a history of hypertension and smoking presented to the emergency department with retrosternal chest pain for two hours duration. He was found to have ST elevation in leads V1 - V4 and was labeled as anterior wall myocardial infarction. PCI was performed successfully to his left anterior descending artery. Two days later, he developed chest pain with dynamic electrocardiogram changes in the inferior leads. For these reasons, he was sent to the cardiac catheterization laboratory for PCI to the right coronary artery (RCA).

In the Cath Lab, JR4 guide catheter was passed through his right radial artery to the RCA ostium. Advance ® wire 0.014 was used to wire the artery with the wire tip placed in the posterior left ventricle (PLV) branch. The PLV has an early take-off from the main vessel with a tortuous course [Figure 1]a. A pseudo-lesion appeared at the proximal segment of PLV following the wiring [Figure 1]b. Withdrawal of wire from PLV branch resulted in a complete resolution of the pseudo-lesion. Guidewire was then re-introduced to the posterior descending artery (PDA) branch [Figure 2]a. This action resulted in similar diffused narrowing along the length of the PDA [Figure 2]a. Both vessels were refractory to intracoronary nitroglycerine injection.
Figure 1: (a) A coronary angiography of the right coronary artery demonstrating a proximal stenotic lesion of 80% (b) a new stenotic (arrow) lesion appeared in proximal posterior left ventricle branch

Click here to view
Figure 2: (a) Guidewire-induced diffused posterior descending artery narrowing (b) poststenting of proximal true lesion and the appearance of new stent edge stenosis (arrow)

Click here to view


A rapid predilatation and stenting of the true proximal lesion was done to avoid ischemia secondary to the pseudo-lesion.

Poststenting, the guidewire was completely removed from the PDA resulting in the disappearance of the PDA pseudo-stenosis. However, a new lesion was noted at the proximal edge of the stent [Figure 2]b, which was suggestive of stent edge dissection. Intracoronary nitroglycerin (200 mg) was injected three times without any response. A partial disengagement of the guide catheter from the ostium of RCA resulted in the resolution of this lesion [Figure 3].
Figure 3: The final angiography after removal of the guidewire and guide catheter showing complete resolution of new lesions

Click here to view



   Discussion Top


Stenoses that appear after placement of the interventional guidewire in a tortuous artery and disappear when the wire is withdrawn are known as pseudo-lesions.[1] This effect is known as the accordion effect or concertina effect.

A number of cases were reported describing these pseudo-lesions which are known either as accordion phenomenon or concertina effect phenomenon. These phenomena are usually seen as consequences of straightening of the tortuous segment of coronary artery. Typically, the accordion phenomena were precipitated by a stiff guidewire causing an invagination and beading appearance of the vessel.[2],[3],[4] The most commonly affected arteries are left internal mammary artery and RCA.[3],[4] Only a few cases were reported where these phenomena appeared after soft guidewire use (and in our case, soft hydrophilic wire). The main risk factors for accordion effects are tortuous vessel, the use of stiff guidewire, and a small number of side branches.[1] From our experience, the risk factors traditionally associated with coronary spasm such as cigarette smoking, hypertension, and female gender also contribute to this phenomenon. What makes our case more interesting was that these phenomena were observed with both the guidewire and the catheter. Interestingly, the catheter-induced segmental spasm was away from the RCA ostium where the engagement of the catheter took place.

This case described both soft hydrophilic guidewire- and guide catheter-induced coronary pseudo-lesions that were refractory to intracoronary nitrate injection but responded promptly to the instruments' withdrawal (guide wire and guide catheter). Such events by themselves do not cause significant clinical sequelae, although a few cases have described hemodynamic compromise and ischemia as a result of the accordion/concertina phenomena.


   Conclusion Top


Recognition of such phenomena is crucial to avoid unnecessary intervention that is correlated with higher procedural risk.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Muller O, Hamilos M, Ntalianis A, Sarno G, De Bruyne B. Images in cardiovascular medicine. The accordion phenomenon: Lesson from a movie. Circulation 2008;118:e677-8.  Back to cited text no. 1
[PUBMED]    
2.
Kim W, Jeong MH, Lee SR, Lim SY, Hong YJ, Ahn YK, et al. An accordion phenomenon developed after stenting in a patient with acute myocardial infarction. Int J Cardiol 2007;114:E60-2.  Back to cited text no. 2
    
3.
Grewe K, Presti CF, Perez JA. Torsion of an internal mammary graft during percutaneous transluminal angioplasty: A case report. Cathet Cardiovasc Diagn 1990;19:195-7.  Back to cited text no. 3
    
4.
Davidavicius G, Manoharan G, De Bruyne B. The accordion phenomenon. Heart 2005;91:471.  Back to cited text no. 4
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Case Presentation
   Discussion
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed4205    
    Printed108    
    Emailed0    
    PDF Downloaded106    
    Comments [Add]    

Recommend this journal