Login | Users Online: 1958  
Home Print this page Email this page Small font sizeDefault font sizeIncrease font size   
Home | About us | Editorial board | Search | Ahead of print | Current Issue | Archives | Submit article | Instructions | Subscribe | Advertise | Contact us
 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 22  |  Issue : 2  |  Page : 102-107

Comparison of long-term complications of using amplatzer ductal occluder and ventricular septal defect occluder for transcatheter ventricular septal defect closure


Pediatric Cardiovascular Research Center, Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran

Correspondence Address:
Dr. Negin Salemi
Pediatric Cardiovascular Research Center, Cardiovascular Research Institute, Isfahan University of Medical Sciences, Isfahan
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/HEARTVIEWS.HEARTVIEWS_166_20

Rights and Permissions

Background: Ventricular Septal Defect (VSD) is the most common type of congenital heart disease and perimembranous type is the commonest form of these defects. Trans-catheter management of these defects is a challenging procedure. Objectives: The purpose of this study was to compare of Trans-catheter closure of perimembranous ventricular septal defect (PMVSD) using Amplatzer Ductal Occluder (ADO) and VSD occluder and their complications and follow-up. Patients and Methods: Between 2013 and April 2019, 69 patients underwent percutaneous closure of PMVSD using ADO (29 patients) and VSD occluder (40 patients). After obtaining the size of VSD from the ventriculogram at least 2 mm larger than the orifice diameter of VSD at the right ventricular side was chosen. The devices were positioned after verification of the proper device position by echocardiography, aortogram and left ventriculography. Results: The mean age of patients were 9.07 ± 7.73 years, mean weight 26.12 ±16.25 kg. The mean defect size of the right ventricular orifice and device sizes were 5.54 ± 1.83 mm 7.72 ± 1.94 mm respectively. Small residual shunts were seen at the completion of the procedure, but they disappeared during follow-up in all but one patient. Two patients had mild AI before the procedure in ADO group that disappeared during the follow-up. The mean follow-up period was 3.3 ± 1.7 years (range 1 to 6 years). Complete atrioventricular block (CAVB) was seen in one patient (VSD occluder) during the procedure that disappeared after the retrieval of the device. Major complication or death was not observed in our study. Conclusions: Trans-catheter closures of PMVSD with ADO or VSD occluder had similar effects in these patients and are safe and effective treatment associated with excellent success and closure rates. Long-term follow-up in a large number of patients is warranted.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1910    
    Printed114    
    Emailed0    
    PDF Downloaded42    
    Comments [Add]    

Recommend this journal