Login | Users Online: 372  
Home Print this page Email this page Small font sizeDefault font sizeIncrease font size   
Home | About us | Editorial board | Search | Ahead of print | Current Issue | Archives | Submit article | Instructions | Subscribe | Advertise | Contact us
 


 
Table of Contents
CASE REPORT
Year : 2021  |  Volume : 22  |  Issue : 4  |  Page : 297-299  

Anterograde crossing of a bicuspid aortic valve through transseptal access to facilitate transcatheter aortic valve implantation


Department of Cardiothoracic, James Cook University Hospital, Middlesbrough, TS4 3BW, UK

Date of Submission18-Feb-2021
Date of Acceptance21-Dec-2021
Date of Web Publication11-Feb-2022

Correspondence Address:
Dr. Paul Williams
James Cook University Hospital, Middlesbrough, TS4 3BW
UK
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/HEARTVIEWS.HEARTVIEWS_27_21

Rights and Permissions
   Abstract 


Transcatheter aortic valve implantation (TAVI) for bicuspid aortic valve stenosis can pose several technical challenges including difficult valve crossing. We report the case of a 77-year-old woman undergoing transfemoral TAVI for symptomatic severe bicuspid aortic stenosis. It proved impossible to cross the bicuspid aortic valve retrogradely despite the use of multiple catheters and wires and attempts by two interventional cardiologists. We describe a novel approach to antegrade crossing, through a transseptal access, to permit retrograde implant of prosthesis.

Keywords: Aortic stenosis, bicuspid valve, transcatheter aortic valve implantation


How to cite this article:
Bawamia B, Muir D, Vijayan S, Williams P. Anterograde crossing of a bicuspid aortic valve through transseptal access to facilitate transcatheter aortic valve implantation. Heart Views 2021;22:297-9

How to cite this URL:
Bawamia B, Muir D, Vijayan S, Williams P. Anterograde crossing of a bicuspid aortic valve through transseptal access to facilitate transcatheter aortic valve implantation. Heart Views [serial online] 2021 [cited 2023 Mar 22];22:297-9. Available from: https://www.heartviews.org/text.asp?2021/22/4/297/337541




   Introduction Top


Transcatheter aortic valve implantation (TAVI) for the treatment of bicuspid aortic stenosis (AS) is accompanied by technical challenges including difficult valve crossing.[1]

We report a case of an elderly frail woman undergoing TAVI during which we could not cross the bicuspid stenosis valve in a retrograde manner. We hereby describe the novel steps of an anterograde crossing through transseptal access to facilitate TAVI.


   Case Presentation Top


A 77-year-old frail woman underwent workup for symptomatic severe AS. Echocardiographic parameters showed peak and mean transvalvular gradients of 67 mmHg and 33 mmHg, respectively, a calculated aortic valve area of 0.65 cm2 and normal left ventricular systolic function. Her preprocedural computed tomography demonstrated a bicommissural raphe-type bicuspid aortic valve [Figure 1]a with mild aortic root dilatation (41 mm) and identified the left femoral artery for access. Coronary angiography revealed severe three-vessel coronary artery disease which was managed medically in the absence of angina. After being deemed too high risk for surgery by the heart team, she attended for TAVI.
Figure 1: Bicuspid aortic valve with the right-left fusion (a). Transseptal puncture through right femoral vein access with SL1 sheath (→) and BRK1-XS needle (*) (b). A 0.032” wire (*) was placed in the left upper pulmonary vein (c). En Snare (*) delivered through 7Fr JR4 guide used to snare antegrade wire into the aorta (d). JR4 guide (*) passed into the left ventricle over wire loop and standard wire unsnared and swapped to a Safari wire (→) (e). Deployment of 26 mm S3 (Edwards Lifesciences) (f)

Click here to view


The right radial artery and right femoral vein were accessed for the placement of a pigtail catheter in the aortic root and a temporary pacing wire, respectively. A 14-French eSheath (Edwards Lifesciences) was inserted into the left femoral artery after double ProGlide (Abbott Vascular) preclosure. It proved impossible to cross the bicuspid aortic valve retrogradely despite the use of multiple catheters and wires and attempts by two interventional cardiologists.

After more than 1 h had passed, it was decided that an alternative strategy was required. An SL1 sheath (St. Jude Medical) was inserted using the established right femoral venous access. Transseptal puncture was then performed with a BRK1-XS (St. Jude Medical) needle with fluoroscopic guidance [Figure 1]b, and a 0.032” wire was placed in the left upper pulmonary vein [Figure 1]c to maintain access to the left atrium. A JR4 diagnostic catheter was used to direct an exchange length hydrophilic 0.035” guidewire (Glidewire, Terumo) into the left ventricle and then through the aortic valve into the aorta. This wire was snared in the aorta through a 7 Fr JR4 guide (EN Snare, Merit Medical) to form an arteriovenous rail [Figure 1]d. The guide catheter was then passed retrogradely across the aortic valve into the left ventricle over the arteriovenous rail. The rail was disconnected, and a Safari Small wire (Boston Scientific) was placed through the JR4 guide catheter directly into the left ventricular cavity [Figure 1]e. The SL1 sheath was removed from the left atrium and a temporary pacing wire was placed into the right ventricle. A 26 mm S3 TAVI (Edwards Lifesciences) was implanted directly in an optimal position with no resultant aortic regurgitation [Figure 1]f. The patient was discharged home the following day.


   Discussion Top


Landmark TAVI trials have excluded bicuspid aortic valve anatomy due to mainly theoretical risks of increased procedural complications.[2] Bicuspid aortic valve anatomy including bulky asymmetric leaflet calcification and ascending aortic dilatation poses challenges to treatment with TAVI. Nonetheless, there is a small, but not insignificant, proportion of octogenarians and nonagenarians with bicuspid aortic valve disease requiring intervention.[3] Due to the high surgical risk in those patients, TAVI may provide an alternative treatment option. Large registry studies of patients treated with modern generation valves have demonstrated similar outcomes for bicuspid valves when compared to tricuspid valves.[4],[5]

There are several technical challenges when treating bicuspid aortic valve disease including challenging valve crossing. This was evident in our case where we had to perform anterograde crossing of the aortic valve after a prolonged unsuccessful attempt at retrograde crossing. This was enabled by a transseptal puncture allowing passage of a guidewire into the left ventricle, through the aortic valve into the aorta.

Antegrade transseptal approach with antegrade deployment of the prosthesis has been utilized in the early phase of TAVI but is now reserved for cases where there are no other suitable access sites.[6] In our case, we already had large bore femoral access, and we were therefore able to snare the guidewire, pass a guide catheter into the left ventricle retrogradely and exchange to a Safari wire, allowing standard retrograde implantation of the prosthesis.


   Conclusion Top


TAVI for bicuspid aortic valve stenosis can be challenging. In this case, we were unable to cross the valve retrogradely. We subsequently demonstrated a safe and effective approach to antegrade crossing, through a transseptal access, to permit retrograde implant of prosthesis.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given his/her consent for images and other clinical information to be reported in the journal. The patient understands that his/her name and initials will not be published and due efforts will be made to conceal his/her identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

PW has received speaker and proctor fees from Abbott Vascular.

DM has received speaker and proctor fees from Abbott Vascular and Edwards Lifesciences.

BB and SV have no conflicts of interest to declare.



 
   References Top

1.
Das R, Puri R. Transcatheter treatment of bicuspid aortic valve disease: Imaging and interventional considerations. Front Cardiovasc Med 2018;5:91.7  Back to cited text no. 1
    
2.
Holmes DR Jr., Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR, et al. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J Am Coll Cardiol 2012;59:1200-54.  Back to cited text no. 2
    
3.
Roberts WC, Ko JM. Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation. Circulation 2005;111:920-5.  Back to cited text no. 3
    
4.
Makkar RR, Yoon SH, Leon MB, Chakravarty T, Rinaldi M, Shah PB, et al. Association between transcatheter aortic valve replacement for bicuspid vs. tricuspid aortic stenosis and mortality or stroke. JAMA 2019;321:2193-202.  Back to cited text no. 4
    
5.
Halim SA, Edwards FH, Dai D, Li Z, Mack MJ, Holmes DR, et al. Outcomes of transcatheter aortic valve replacement in patients with bicuspid aortic valve disease. Circulation 2020;141:1071-9.  Back to cited text no. 5
    
6.
Misumida N, Anderson JH, Greason KL, Rihal CS. Antegrade transseptal transcatheter aortic valve replacement: Back to the future? Catheter Cardiovasc Interv 2020;96:E552-6.  Back to cited text no. 6
    


    Figures

  [Figure 1]



 

Top
 
  Search
 
    Similar in PUBMED
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Case Presentation
   Discussion
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed1367    
    Printed52    
    Emailed0    
    PDF Downloaded44    
    Comments [Add]    

Recommend this journal